Oil filled with connector, 0 to 30 ft range, 50 ft cable

Oil filled with connector, 0 to 30 ft range, 50 ft cable
Artikel-Nr.: 77074-050
Einzelpreis Kontakt

Single point calibration - zero cal only

Robust Sensor

Streamlined Design

Minimal Sensor Fouling

Oil-filled Submerged AV sensor models are great solution for monitoring sites that are susceptible to fouling of the pressure transducer. The cavity is filled with high-viscosity silicon oil to reduce the collection of sand, silt and grit on the pressure transducer. Use the non-oil-filled cover plate model in sites where the pipe could run dry. Either way, we’ve thought about the little details that will reduce your maintenance or lost data hassles.

Greater Directivity

Technische Daten

Abmessungen (H x B x T): 23 mm x 38 mm x 135 mm
Allowable Level: Standard: 10.5 m (34.5 ft)
Extended: 31.5 m (103.5 ft)
Bestimmungsgrenze: 0 to 30 ft range
Betriebsbedingungen: 0 - 70 °C
Genauigkeit: LEVEL MEASUREMENT: ±0.16% full scale ±1.5% of reading at constant temp (±2.5ºC) ±0.20% full scale ±1.75% of reading from 0 to 30ºC (32 to 86ºF); ±0.25% full scale ±2.1% of reading from 0 to 70ºC (32 to 158ºF)
  Velocity-Induced Depth Error Compensated based on flow velocity
  VELOCITY MEASUREMENT: ±2% of reading or 0.05 fps** **Uniform velocity profile, known salinity, positive flow. Field performance is site specific.
Gewährleistung: 6 Monate
Kabel: Urethane sensor cable with air vent
Kabellänge: 50 ft
Kompatible Geräte: 920, 930, 930T, 950, 900 Max Samplers, and AV9000 Interface Analyzer Module
Level Accuracy: ±0.16% full scale ±1.5% of reading at constant temp (±2.5ºC)
±0.20% full scale ±1.75% of reading from 0 to 30ºC (32 to 86ºF)
±0.25% full scale ±2.1% of reading from 0 to 70ºC (32 to 158ºF)
Level Measurement Method: Differential pressure transducer with stainless steel diaphragm and atmospheric pressure reference
Material: Noryl outer shell with epoxy potting within
Messbereich (2): -1,52 m/s - 6,10 m/s
Messmethode: LEVEL: Pressure transducer with stainless steel diaphragm
Oil or Non-Oil Filled: Oil filled with connector
Spezielles Ausstattungsmerkmal: Oil Filled, 50 ft cable
Tiefe: Typical Minimum Operating Depth 2 cm
Typical Minimum Operating Depth: 2 cm (0.8cm)
Velocity Accuracy: ±2% of reading or 0.05 fps**
**Uniform velocity profile, known salinity,
positive flow. Field performance is site specific.
Velocity-Induced Depth Error: Compensated based on flow velocity
Velocity Measurement Method: Doppler ultrasonic;
twin 1 MHz piezoelectric crystals